Authors

Abdulwahab Alahmari

Institutions

Ministry of Health

Logo
  • Currently 5.00/5
  • 1
  • 1
  • 2
  • 2
  • 3
  • 3
  • 4
  • 4
  • 5
  • 5

Rating: 5.0/5 (2 votes cast)

Theme

Diagnostic & Interventional Radiology

Title

The accuracy of the MTA visual grading system for AD patients

Background

The MTA grading system is a very famous grading system for Alzheimer's disease. This grading system is a visual grading system that has been used by neurologists, psychiatrists, and neuroradiologists all over the world.the MTA grading system into grades from 0 = normal, 1 = minimal atrophy, 2 = mild atrophy, 3 = moderate,atrophy, to 4 = severe atrophy (Scheltens, 1995)1.

 

 

Summary of Work

The aim of this poster is to test the accuracy of the MTA grading system. A 60 Alzheimer's disease (AD) patients will be evaluated based on the MTA grading system criteria. Then a normality analysis test will be run to check how many are normal among the group who already been diagnosed with AD.

Summary of Results

The result showed that the MTA is not sensitive in stages 0, 1, and 2, but accurate with stage 3 and 4. This finding has been found in another research that supports this poster's findings 2.  The MTA classified the AD patients in stages 1 and 2 as normal patients (see Table 1 and 2).

 

Table1: MTA groups

Cumulative Percent Percent  Frequency  MTA grade
31.7% 31.7% 19 1
61.7% 30.0% 18 2
81.7% 20.0% 12 3
100.0 18.3% 11 4
  100% 60 Total

 

Table 2: Normality analysis

Cumulative Percent Percent Frequency  MTA normality
43.4% 43.4% 26 Normal
100% 56.6% 34 Abnormal
  100% 60 Total

 

Conclusion

The MTA classified the patients who already diagnosed as AD patients in grades 1 and 2 as normal which means the MTA grading system must be replaced.

Take-home Messages

The MTA is an inaccurate grading system that still used worldwide. It must be changed into a measurable grading system.

References

1-Scheltens P, et al. Visual assessment of medial temporal lobe atrophy on magnetic resonance imaging: interobserver reliability. J Neurol. 1995 1;242(9):557-60.

2-Varon D, et al. Visual rating and volumetric measurement of medial temporal atrophy in (ADNI) cohort: baseline diagnosis and the prediction of MCI outcome. int. 2015 30(2):192-200.

Background
Summary of Work
Summary of Results
Conclusion
Take-home Messages

The MTA grading system is an inaccurate grading system and it must be replaced with a grading system with measurable values.

References
Send ePoster Link